Control Panel Menu Tree Guide
(Press MENU SELECT Button)
Press the MENU SELECT button to view each screen. While in the menu screens, if no activity is detected after 15
seconds, the main screen is displayed.
HEAT MODE
POOL
POOL IDLE
SET=
ACT=
SPA IDLE
SET=
ACT=
HEAT/COOL/AUTO
SET TO-
HEATPUMP TIMER
REMAINING=
REMOTE MODE
OFF
AUTOSET
OVERRIDE IS
EXTEND
HEAT
OVERRIDE IS
RESTART DELAY
REMAINING=
SUCTION TEMP
ACTUAL=
ALARM STATUS
NONE
*
Menu appears only if Autoset or Extend
is enabled at the factory.
**
Menu appears only if a delay is active
***
Display return to this view after 15
sec of inactivity
14
UltraTemp®-E
1. Auto Mode Screen
Displays whether the heat pump is in Heat only, Cool only or Auto
mode. It also displays whether the Pool or Spa set point is active. The
active set point can be switched between Pool and Spa by using the
UP and DOWN arrows.
2. Pool and Spa Run Screens
°C
Displays whether the heat pump is idle, heating or cooling if the Pool
***
or Spa set point is active. Displays the water temperature set point
and the actual measured water temperature.
°C
3. Heat or Cool Mode Selection Screen
This screen is only shown on Auto Heat and Cool heat pumps. This
screen allows the operator to switch the heat pump between heat-
only, cool-only and auto heat/cool modes by using the UP and DOWN
arrows.
HEAT
4. Heat Pump Timer Screen
This feature is an adjustable timer to allow the heat pump to run
(green LED ON) and then turn OFF (green LED OFF) for a
4:30
predetermined amount of time.
5. Relay Remote On/Off Screen
Allows the operator to turn the Relay Remote mode On and
Off. In Relay Remote mode, the heat pump is controlled by an
external thermostatic controller.
.Note: When using RS485 communication cable, the relay
HEAT
remote must be turned off.
OFF
6. AutoSet On/Off Screen
*
This menu allows the operator to turn the AutoSet mode On and Off.
AutoSet mode periodically energizes a filter pump contactor to start
a remote filter pump which allows the heat pump to heat or cool the
OFF
*
water as necessary.
7. Extend On/Off Screen
This menu allows the operator to turn the Extend mode On and Off.
1:00
Extend mode will keep the filtration active until the SET temperature
**
is reached.
8.Time Delay Screen
If the heat pump is waiting on any restart, pump start, or sensing
24°C
water temperature delays, this screen shows how much delay time is
left.
9. Suction Temperature Screen
Shows the suction line temperature of the refrigerant. This screen
appears if the defrost is enabled.
10. Alarm Screen
Shows if an alarm condition is present. If no alarms are present the
screen will display ALARM STATUS NONE. The control board has the
ability to store a 30 Alarm history of previous alarms that have
occurred. At the alarm status screen, press the DOWN arrow. The
first alarm will be the most recent alarm that has occurred.
Successive presses (up to 30) of the DOWN arrow will display the
alarm history in the order of occurrence The operator can scroll back
up using the UP button. There is an option to erase the history.