5.5. LOCATING FAILURES
SYMPTOMS
The screen is turned off
An alarm sounds and the
process has not finished
The device has reduced
effectiveness when heating
The device works but it does
not heat up
Other malfunctions
6. MAINTENANCE
Follow the instructions below for any maintenance tasks:
• Main body:
· Always power the device down and unplug it before proceeding with any cleaning
tasks.
· Only use a damp cloth to clean it.
• Heating chamber:
· Depending on the quality of the water used, lime deposits may build up over time at
the base of the heating chamber.
· These lime deposits must be removed regularly by pouring a mixture of 100 ml of hot
water and 100 ml of white vinegar into the heating chamber. Pour directly into the
basin and allow to soak for around 30 minutes. Subsequently, empty the receptacle
and wipe it with a damp cloth.
· There are specific products on the market for removing lime from this type of device;
they can also be used to clean it. In any case, before using them, make sure that
they are not abrasive.
• Removable accessories:
· The plastic hood and heating basket are dishwasher safe.
7. TECHNICAL SPECIFICATIONS
• Voltage: 220-240 V AC.
• Frequency: 50-60 Hz.
• Consumption: 500 W.
8. INFORMATION ABOUT THE DISPOSAL OF THE PRODUCT
It is necessary to dispose of the product in a responsible fashion. For this
reason, if the product shows a symbol of a rubbish bin with an X through it,
do not dispose of it together with other domestic waste. Once its service life
has reached its end, these products must be disposed of by taking them to
a collection and treatment centre which has been designated by the local
authorities. You can also get in touch with the establishment where you
purchased the product for your tank.
POSSIBLE CAUSES AND CORRECTIVE
MEASURES
Check that the device is plugged in and push
the power button
There is not enough water in the heating
chamber. Replenish it and restart the process
Check if there are any lime deposits in the
heating chamber. Clean the chamber by
following the instructions in point 6 as many
times as may be necessary nor normal
operation to be restored
Get in touch with the Miniland technical service
19