The equipment can be used wherever you want to
move water, e.g. in the house, in the garden, and
for many other applications. It must not be used to
operate swimming pools!
If you want to use the equipment in bodies of wa-
ter with a natural, muddy bottom, place the equip-
ment in a slightly elevated position, e.g. on bricks.
The equipment is not designed for continuous
operation, e.g. as a circulating pump in a pond. In
this case the equipment's anticipated life will be
greatly shortened because the equipment was
not designed for continuous loading.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
The water may be contaminated by escaping lub-
ricating oil/lubricant.

4. Technical data

Mains connection .................... 220-240 V ~ 50 Hz
Power rating ............................................. 1000 W
Max. pumping rate ...................................6500 l/h
Max. delivery head ....................................... 45 m
Max. submersion depth ................................ 19 m
Max. water temperature ............................... 35°C
Hose connection ...........approx. 42 mm (11/4") IG
Max. size of foreign bodies: ................. clear water
Protection type. .............................................IPX8
Power cable ................................................. 22 m

5. Before starting the equipment

Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Anl_NTP-E_100_SPK7.indb 14
Anl_NTP-E_100_SPK7.indb 14
GB
5.1 Installation
The equipment can be installed either:
Stationary with a rigid pipe line
or
Stationary with a flexible hose line
Notice!
Before you use the pump, clarify any possible
special conditions which need to be fulfi lled for
the installation!
For example, additional safety measures may be
needed if damage to property could result from a
power failure, soiling or a defective gasket.
Examples of such safety measures:
Pumps running in parallel on a separately protec-
ted power circuit, moisture sensors for switching
off the pumps, and similar safety arrangements.
Be sure to consult a professional plumber if you
have any doubt.
The maximum pumping rate is possible only with
the largest possible line diameter; if smaller hoses
or pipes are connected, the pumping rate will be
reduced.
When installing, never hang the equipment by
the discharge line or by the power cable. The
equipment must be hung up with the provided
suspension eyelets or it must rest on the bottom
of the shaft. To ensure that the equipment works
properly, the bottom of the shaft always must be
free of sludge and other accumulations of dirt. If
the water level is too low, the sludge in the shaft
can quickly dry out and hinder the equipment
from starting. It is necessary therefore to check
the equipment regularly (carry out trial start-ups).
The pump shaft should be large enough.

5.2 Mains connection

Danger!
The equipment you have purchased comes with
an earthing-pin plug. The equipment is designed
for connection to a socket outlet with earthing
contact for 220-240 V ~ 50 Hz. Make sure that the
socket-outlet is suffi ciently fused (at least 6 A)
and in good working order. Insert the power plug
in the socket-outlet and the equipment is ready
for operation.