Power Requirements - Bosch NEM Serie Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Table 1: Counter Top Cutout Dimensions
Model
#
NEM73
B
C
NEM93
B
C

Power Requirements

Minimum
Inches / (mm)
19-7/8" / (505 mm)
28-3/4" / (731 mm)
19-7/8" / (505 mm)
34-3/4" / (883 mm)
*For solid surface countertop installations, use maximum cutout dimensions and
consult surface manufacturer for specific cutting instructions.
Power Supply is dual rated: 240 Volts or 208 Volts, 3 wire, 60 Hz, with the follow-
ing circuit breaker requirements:
Model NEM73: 30 Amp circuit breaker
Model NEM93: 40 Amp circuit breaker
All Models: 240 Volt, 3 Wire, 60 Hz / 208 Volt, 3 Wire, 60 Hz
Connect only to a 3-wire 120/240 or 120/208 volt AC system. The neutral is not
required for the operation of this appliance but an independent ground is required.
Install a junction box (not supplied), below the counter top within 3 feet (91.4 cm)
of flexible conduit (supplied) located at the left rear corner of the cooktop rough-in
box. Plan the installation of the unit so the location of the junction box is within 3
feet (91.4 cm) of the left rear of the cooktop bottom. It must be accessible from the
front of the cabinet.
Figure 3 - Junction Box Installation
Inches / (mm)
20" / (508 mm)
28-7/8" / (734 mm)
20" / (508 mm)
34-7/8" / (886 mm)
Conduit
(approx 3 ft.(91.4 cm))
12"
(30.4 cm)
(approx)
"j" Box
Maximum
English 3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Nem 73Nem 93

Table des Matières