Displays for 1s :
6
« no battery »
+ alarm beep
The device is locked in Showroom
7
mode
Screen displays :
8
« #error T(°C) »
+ alarm beep
Screen displays :
9
« #error IHM »
+ alarm beep
Screen displays :
10
« #error fuse »
+ alarm beep
11
The device doesn't display anything
GYSFLASH 100.12 HF / 102.12 HF
Showroom mode is working on
« no battery »
Lock Showroom active
Faulty fan
Extended exposure to sunlight
Electronic fault
Mishandling
Input fuse HS
Faulty electrical network
Showroom without battery : GYSFLASH operating normally.
To deactivate the "no battery" function, press the "START/STOP" key, and then
press the "START/STOP" key again to start the Showroom mode with battery.
Normal operation of GYSFLASH.
Refer to configuration menu to deactivate this function.
Contact your distributor.
Do not leave the device exposed to sunlight.
Leave the device ON until the fault disappears. (The alarm beep can be stoppe-
dPossibility to stop the alarm beep by pressing the START/STOP key).
Contact your distributor.
Internal fuse must be changed by a qualified person
(ref. 054585 : 125A).
Input fuse must be changed by a qualified person
(temporised fuse 10A 5x20).
Check the voltage of the electrical network is between 180V and 260V.
EN
21