If the following phenomenon takes place, it is not an irregular trouble. Please check again
before consulting your service shop.
Phenomenon
When used for the first time, smoke or
smell comes out of the heater.
At the time of ignition or shut-down of the
heater, noise comes from the burner section.
Specifications
7
Model Type
Type
Ignition System
Fuel
Fuel Consumption
Heat Output Rating
Tank Capacity
Continuous Operating Time
Dimensions (mm)
Weight (w/empty tank)
Power Voltage and Frequency
Power Consumption
Electric Fuse
Operating Noise Level
Safety Systems
Standard Parts
Wiring Diagram
Photo Cell
Operation Switch
Option
Overheat Sensor
Lamp
Because fuel is burning together with dusts, etc. This phenomenon will
disappear after a short while.
Noise is caused by expansion or shrinkage of the burner section due to
temperature's up and down. This is not irregular.
HG 125NA
Forced Air/Direct-fired
High Intensity Discharge
Kerosene or Fuel-Oil no heavier than No.2 (Diesel)
2.9 kg/h (0.9 gal/h)
34 kW (116000BTU/hr)
54
(14 gallon)
15 hours
780 (H) x 565 (W) x 712 (D) Outlet Diameter Ø318
37 kg, 81.6 lbs
AC 110–120V 50/60Hz
• When igniting: 176W • When burning: 150W
3 A
69dB (A)
• Flame Monitor • Overheat Prevention System • Anomaly detection system for fan motor
• Fuse (3A) x 1 • Element x 2 • Nozzle x 1 • Nozzle Wrench x 1 (Put in a plastic bag)
Circulation Motor
Explanation
Solenoid
Pump
Fan Motor
Fuse
Power Source
Transformer
Igniter