Specifications
Heater Specifications
Type
Ignition System
Fuel
Fuel Consumption
Heat Output
Dimensions (H×D×W)
Dry Weight
Power Supply
Power Consumption
Fuse Type
Noise Level
Safety Systems
Accessory
Gas Requirement
Inlet pressure
Manifold pressure
Wiring Diagram
VAL6 GN5
Radiated direct flame
High intensity discharge
Natural gas
137 CFH / 6.1 lbs/h
144,000 BTU/h / 42.2 kW
35.3 x 31.7 x 30.3 inch / 896 x 804 x 770 mm
108.1 lbs / 49 kg
120 V 60 Hz
When igniting: 107 W
When burning: 93 W
Flame monitor (Flame-rod)
Overheat protection
Tip-over switch
Hose (GN5/GP5)
GN5 (Natural gas)
Max. 7.0 IN. WC.
Min. 5.0 IN. WC.
1.8 IN. WC.
VAL GP5
Propane gas
55.8 CFH / 6.6 lbs/h
3.0 A
60 dB (A)
Air switch
GP5 (Propane gas)
Max. 11.0 IN. WC.
Min. 10.0 IN. WC.
1.5 IN. WC.
Be sure to use regulator for cylinder which
inlet pressure range is 25 - 250psi
8