1- Place the batteries inside the remote control.
2- Open water supply valve
3- Activate the power to supply the In-Wash.
4- After connecting the power, you have 60 seconds to link the remote control, pressing simultaneously the Drying and Stop buttons on the remote
control for 5 seconds.
5- A beep will be heard and all the LEDs on the remote light up, as a signal that it is connected. A self-calibration process starts for 120 seconds during
which water flows from the e-bidet nozzle window.
Do not disconnect the device during this process.
Should the connection be incomplete, repeat the process starting from step 2.
2.2.2 USE OF THE PRODUCT
The In-Wash has a small internal water tank that is cold in stand-by conditions.
When the user detector detects a seated user, the preheating process is activated.
The preheating takes place at 36º. The functions may be activated at any time, but if they are activated too soon, the water will not have time to reach
the established temperature; therefore it is recommended a minimum preheating period of 30 seconds from the moment the In-Wash detects the user
until any water function is activated.
When a function is activated, the In-Wash carries out a cleaning of the nozzle before its use.
When the function is finished, a subsequent cleaning process of the nozzle takes place for 10 seconds.
The functions may only be activated when the cover is open and the device detects a user.
See Fig. 2
It is possible to modify the pre-set standard values, customising them to suit the customer´s needs. See section 3.4.1
When pressing any button of the remote control, the leds are activated, informing us of the active function and the settings that have been selected.
The leds switch off 5 seconds after showing that information.
3. OPERATION
3.1 FUNCTIONS BY REMOTE CONTROL
❚
3.1.1 PERINEAL CLEANING FUNCTION
By selecting this function the nozzle is activated in the
advanced position (for female cleaning).
With the function activated, if the same button is pres-
sed again the oscillating function is activated. If it is
pressed again, we return to the normal mode (not os-
cillating).
While using this function it is possible to adjust:
• Water temperature.
• Water pressure.
• Position of the nozzle to adjust it properly to the user.
To stop this function, press the Stop button on the re-
mote control or on the auxiliary side control.
The cleaning stops after 2 minutes if no other button
is pressed.
If another function is chosen while the cleaning is taking
place, the cleaning stops and the selected function is ac-
tivated.
3.1.3 DRYING FUNCTION
This function provides air for drying after the cleaning
functions.
While using this function it is possible to adjust:
• Air temperature.
To stop this function press the Stop button on the re-
mote control or the auxiliary side control.
The drying stops after 3 minutes if no other button is
pressed.
If another function is chosen while the drying is taking
place, the drying stops and the selected function is ac-
tivated.
18
3.1.2 ANAL CLEANING FUNCTION
By selecting this function the nozzle is activated in the
rear position.
With the function activated, if the same button is pres-
sed again the oscillating function is activated. If it is
pressed again, we return to the normal mode (not os-
cillating).
While using this function it is possible to adjust:
• Water temperature.
• Water pressure.
• Position of the nozzle to adjust it properly to the user.
To stop this function, press the Stop button on the re-
mote control or on the auxiliary side control.
The cleaning stops after 2 minutes if no other button
is pressed.
If another function is chosen while the cleaning is taking
place, the cleaning stops and the selected function is
activated.
3.1.4 STOP FUNCTION
It stops any active function.