9. Failure Messages in ESM-3711HN Heating Controller
1-
Screen Blinking
Sensor failure . Sensor connection is wrong or there is no sensor connection. If buzzer function
selection parameter
2- Main Screen Value is Blinking.
Example : If alarm function selection parameter
and maximum alarm parameter
starts to blink. Also buzzer function selection parameter
10.Optional Accessories
1.RS-485 Module
RS-485 Communication Interface
11.Ordering Information
A BC D E
ESM-3711HN
(77x35 DIN Sizes)
A
Supply Voltage
W
2
24V
( %15) 50/60Hz - 1.5VA
±
V ±
3
24V
( %15) 50/60Hz - 1.5VA
V ±
4
115V
( %15) 50/60Hz - 1.5VA
V ±
5
230V
( %15) 50/60Hz - 1.5VA
10 - 30 V Z
8
BC
Input Type
J ,Fe CuNi IEC584.1(ITS90)
05
K ,NiCr Ni IEC584.1(ITS90)
10
11
PT 100, IEC751(ITS90)
PT 100, IEC751(ITS90
09
PT 1000, IEC751(ITS90)
14
13
PT 1000, IEC751(ITS90
PTC (Not-1)
12
NTC (Not-1)
18
All order information of ESM-3711HN Heating Controller are given on the table at above. User may
form appropriate device configuration from information and codes that at the table and convert it to the
ordering codes. Firstly, supply voltage then other specifications must be determined. Please fill the order
code blanks according to your needs. Please contact us, if your needs are out of the standards.
Note-1:If input type is selected PTC or NTC (BC= 12, 18), Temperature sensor is given with the
device.For this reason, if input type is selected as PTC,sensor type (V = 0,1 or 2) or if input type is
selected as NTC, sensor type (V = 0,3 or 4) must be declared in ordering information.
Your Technology Partner
is 3 or 4, internal buzzer starts to operate.
is 50 When temperature is above 50 °C, value on the screen
/
FG HI /
U V W Z
0
/
00 00
/
1
0
0
Scale(°C)
0°C/32°F ; 800°C/1472°F
0°C/32°F ; 999°C/1830°F
-50°C/-58°F ;
400°C/752°F
-19.9°C/-4°F ;
99.9°C/212°F
-50°C/-58°F ;
400°C/752°F
-19.9°C/-4°F ;
99.9°C/212°F
-50°C/-58°F ;
150°C/302°F
-50°C/-58°F ;
100°C/212°F
Thank you very much for your preference to
use Emko Elektronik products, please visit our
web page to download detailed user manual.
in programming section is 1 (Absolute Alarm)
is 2 or 4, then internal buzzer is on.
ü
2.PROKEY Programming Module
The device is programmed(Upload or
Download) by using the parameters.
Output-1
E
V
1
Relay Output (16(8) A@250 V
SSR Driver
Output (
Maximum 20m, Maximum 17V
2
Temp. Sensor which is given with ESM-3711HN
V
0
None
1 PTC-M6L40.K1.5 (PTC Air Probe 1.5 mt Silicon Cable)
PTCS-M6L30.K1.5.1/8" (PTC Liquid Probe 1.5 mt Silicon Cable)
2
NTC-M5L20.K1.5 (NTC Sensor, thermoplastic moulded with 1.5 m cable
3
for cooling application)
NTC-M6L50.K1.5
(NTC Sensor, stainless steel housing with 1.5 m cable
4
for cooling application)
Customer
9
V
Þ
c
Z
Þ
W
Þ
can be applied
www.emkoelektronik.com.tr
,at resistive Load, 1 NO )
Z
)
Vac,
Vdc
Vdc or Vac
16