Cooking Time (Timer) Parameter
It can be adjusted from 1 to 999 minutes. When it is 1,
decrement button on the display. So Manual Control is selected. In Manual control, user can
start and stop temperature controlling with cooking ON/OFF button or
start/stop input
.
Selection of Temperature Control and Starting Cooking Time (Timer) Parameter
(Default = 0 ) MODBUS ADDRESS : 40010
Temperature control and cooking time (Timer) starts at power on.
Temperature control starts at power on. Cooking time (Timer) can be started by
pressing cooking ON/OFF button or when
closed condition.
Temperature control and cooking time (Timer) can be started by pressing cooking
ON/OFF button or when
Cooking Time Starting Conditions Parameter
MODBUS ADDRESS: 40011
This parameter can be observed if cooking time (Timer)
Cooking time (Timer) is started with cooking ON/OFF button or when
time start/stop input is getting closed condition.
Cooking time (Timer) is started when temperature reaches to the process set
value after pressing cooking ON/OFF button or when
input is getting closed condition.
Temperature Controlling Continuity Selection Parameter
MODBUS ADDRESS : 40012
Temperature controlling can be continues or stopped according to the selection. This
parameter can be observed if cooking time (Timer)
Continuous Operation : Temperature control starts after the temperature
control starting delay at power on
function selection parameter
internal buzzer operates to indicate cooking time has finished.
Interrupted Operation : Temperature control starts after temperature control
starting delay at power on
at the end of the cooking time (Timer) or by pressing cooking ON/OFF button or
when
cooking time start/stop input is getting open condition.
does not start till cooking ON/OFF button is pressed again or when
start/stop input is getting closed condition again.
Temperature Alarm Function Selection Parameter
MODBUS ADDRESS : 40013
Alarm function is inactive.
Absolute alarm is selected. If temperature lower than
than
, then alarm is on.
Relative alarm is selected. Alarm operates according to the set value.
If temperature is below (Set -
Minimum Alarm Parameter
MODBUSS ADDRESS : 40014
It can be adjusted from minimum scale of the device to maximum alarm value
Maximum Alarm Parameter (Default = Input Type Maximum Scale)
MODBUS ADDRESS : 40015
It can be adjusted from minimum alarm value
Alarm Delay Parameter
If an alarm occurs, delay can be defined with this parameter. It can be adjusted from 0
to 99 minutes.
( Default = 45 ) MODBUS ADDRESS : 40009
cooking time start/stop input is getting closed condition.
( Default = 0 )
Is 1 or 5, at the end of the cooking time, (Timer)
is expired. Temperature control can be stopped
) or above ( Set +
( Default = Input Type Minimum Scale )
( Default = 0 ) MODBUS ADDRESS : 40016
can be observed by pressing
cooking time start/stop input is getting
³
is 1.
cooking time start/stop
( Default = 0 )
³
is
1
is expired and continues. If buzzer
Temperature control
( Default = 0 )
and higher
), alarm occurs.
to maximum scale of the device.
cooking time
cooking
cooking time
.
10

Publicité

Table des Matières
loading