Terminals; Warning Out Terminal; Tape End Out Terminal - Sony SVT-124P Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Terminals

WARNING OUT Terminal

This terminal will help you to know when something
wrong has happened to the VCR during recording.
The VCR outputs a signal from WARNING OUT
terminal.
WARNING OUT terminal
COM terminal
Tape recording stops
Note
To turn the clog detection function off, set CLOG
DETECT to N (no) on the SET UP 3 display.
30
5 V
0 V
To reset, press STOP p or
EJECT 6, if the clog detection
function works and the VCR
gives warning, otherwise, press
ALL RESET.

TAPE END OUT Terminal

When the VCR detects the tape end during recording,
the output level becomes 0 V DC. To resume the 5 V
output, press the operation button (EJECT 6, REC r,
FF ), REW0 or PLAY z, etc.).
COM terminal
TAPE END OUT terminal
REC mode
Tape end
Recording
Rewind
mode
Output
signal
REPEAT REC mode
Tape end
Recording
Rewind
mode
Output
signal
2 sec.
Set TAPE END OUT to –3M or END on the SET UP
3 display.
• –3M: the time counter shows "2H57M" (about three
minutes before the tape end, when using E-180 tape)
and a signal is output from the TAPE END OUT
terminal (recording will be continued to the end of
the tape).
• END: the VCR detects the tape end.
Beginning
Press an
of tape
operation button.
Stop
5 V
0 V
Beginning
of tape
Recording
5 V
0 V

Publicité

Table des Matières
loading

Table des Matières