Connect power control unit
Switch off circuit breaker for cooker/hob.
Unscrew fastening screws (14) of the casing
cover (13) and remove the cover.
Fix cut-out for the flush-mounted installation
(16) or surface-mounted installation (25).
Unscrew device screws (14) of the
flush-mounted/hollow-wall box.
Insert cooker supply cable (17) into the
power control unit (24).
Position the power control unit over the
flush-mounted/hollow-wall box and fasten
with the device screws (15).
In the case of a surface mounting, the
cooker supply cable is inserted through the
second cut-out (25) and the device e.g. is
mounted on the wall behind the cooker.
Connect cookguard 3phase
When connecting a single hob the connect-
ing terminals L1 and L2 are to be assigned.
When connecting a single hob, the free,
third wire must be insulated according to the
installation regulations.
The N-conductors are connected to the
distribution terminal supplied (only 3-phase
variant).
Connect cooker supply cable 3-phase (17)
to the connection terminals IN (19 ... 23) of
the power control unit. When doing so, first
connect the earth conductor.
AUX1
In 1
Out 1
Figure 6: Connecting terminal (AUX) for exter-
nal signal generator
30
OR:
Connect cookguard 1phase
AUX2
Out 2
In 2
Insert the connection cable (27) through the
cable entry (10).
Fix strain relief (26).
Connect the connection cable 3-phase (27)
to the connection terminals OUT (19 ... 23)
of the power control unit. When doing so,
first connect the earth conductor.
Connect cooker supply cable 1-phase (17)
to the connection terminals IN (22/23/29) of
the power control unit. When doing so, first
connect the earth conductor.
Insert the connection cable (30) through the
cable entry (10).
Fix strain relief (26).
Connect the connection cable 1-phase (30)
to the connection terminals OUT (22/23/28)
of the power control unit. When doing so,
first connect the earth conductor.
Optional: Insert water leakage sensor into the
connection socket (12) of the power control unit
(9) (see Mounting Water Leakage Sensor).
Fasten casing cover (13) using the fastening
screws (14) on the lower casing.
Optional: Connect external signal generator
to potential-free contact (18) (Figure 6).
Switch on circuit breaker again for cooker/
hob.
(11)
Figure 7: Connect potential-free output