Scope of delivery
- Power control unit
- Sensor unit with mounting bracket
- white front cover for the sensor unit (pre-as-
sembled)
- transparent front cover for the sensor unit
- Fitting material
- Cleaning pad
3 Function
Function notes
The cookguard is designed to draw attention
to hazards as early as possible and to respond
accordingly. According to the standard EN
50615 the device is able to distinguish between
the normal use of a cooker/hob and a hazard.
Nevertheless, during normal use of the cooker/
hob attention hast to be paid to hazards as the
device cannot detect all possible situations.
The sensor unit monitors the temperature in-
crease and use of the cooker/hob. If a potential
hazard is determined, a pre-alarm is triggered
if necessary. If this is not acknowledged by the
user, the power control unit switches off the
power supply to the cooker/hob after 15 sec-
onds. If the critical situation on the cooker has
been remedied, the pre-alarm can be cancelled
or the power supply to the cooker can be reacti-
vated by pressing the operation button (3) or by
tapping at any position on the sensor unit of the
pre-alarm, if activated.
Correct use
- Ensuring the operational safety of electric
cookers/hobs
- Monitoring the cooking activities and swit-
ching off the cooker after identifying the ha-
zard
- 10 Colour strips for inserting in the transpa-
rent front cover
- 2 Batteries for the sensor unit (AA/LR6)
- 2 connection terminals for N- and PE-con-
ductor connection (3phase)
- 1 connection terminal PE-conductor connec-
tion (1phase)
- Operating and assembly instructions
- The device is only suitable for indoor areas
- Installation of the sensor unit on the wall or
under the extractor hood
- Installation of the power control unit on the
wall or on the floor
- The device is only intended for use in private
households and is not to be used in conjunc-
tion with cookers and hobs as used in com-
mercial kitchens.
- The device is to be used solely for monitoring
electric cookers/hobs up to a maximum width
of 90 cm.
Product characteristics
- Sensor unit with status display via LED (5)
- Display for low battery level via LED (7)
- Adjustable automatic child lock (deactivated by
default).
- Connection for external water leakage sen-
sor (optional, see Accessories)
- Connection for external signal generator via
potential-free contact (optional, see Acces-
sories)
z
23