Technical data

NOTICE
Technical data
Ä
Additional technical data and notices on using the device can be
found in the operating instructions.
CAUTION
UL applications
For UL applications: use is permitted exclusively in Class 2 circuits ac-
cording to NEC.
Operating voltage
Max. power consumption
Light source
Laser class
Wavelength
Impulse duration
Max. output power (peak)
Measurement range
Reproducible accuracy
Output time
Response time
Basis for contouring error calcula-
tion
Polling interval
Max. traverse rate
Beam exit
Reading distance/working range
4.9 ... 5.4 V DC acc. to IEC 742
(10 ... 30 V DC in combination with MA 8-xx,
optional)
1.5 W
Visible red light laser
2 (acc. to IEC 60825-1:2014); see
1
655 nm
< 420 µs
1.7 mW
0 ... 10,000,000 mm
± 1 (2) mm
3.3 ms
26.6 ms (configurable)
13.3 ms
≥ 10 ms
4 m/s
Front
Lateral with deflecting mirror
See
5