RA24NK (DV), RA24PK (DV) RA24BN (BV), RA24BP (BV)
Use with Valor Retrofi re Heater Models RF24D, RF24B, RF24ID or RF24XB ONLY
This appliance is certifi ed for use from 0-4500ft. For
altitudes above 4500ft see local codes.
Kit Contents
• 1 Pilot injector, see chart for identifi cation
• 1 Main burner injector, see chart for identifi cation
• 1 Minimum rate by-pass screw
• 1 Special bit for control cover screw (for RFBV/XB only)
• 1 Set of conversion labels
Tools Required
• Wrenches, to disconnect gas line
• Phillips (+) screwdriver, to remove burner module
• Small jewelers size fl at blade screwdriver, to set pressure
• Small fl at blade screwdriver, to release pressure tap on
valve
• Needle Nose Pliers, to remove by-pass screw
• Hex Allen wrench, 4 mm or 5/32", to remove pilot injector
• Special 2-pin screwdriver tip, supplied with kit, to
remove valve cover
• Manometer, to set pressure
Specifi cations
Fireplace Models
Gas
Altitude (Ft)
Input Max. (Btu/h)
Input Min. (Btu/h)
Manifold pressure (in w.c.)
Min. Supply pressure (in w.c.)
Max. Supply pressure (in w.c.)
Main Burner Injector
Pilot Injector
By-Pass Screw
4000803-07
© 2011 Miles Industries Ltd. All rights reserved.
Gas Conversion Kits
Installation Instructions
RF24DVN
RF24DVP
RF24IDN
RF24IDP
Natural
Propane
24,000
24,000
10,500
10,500
3.95
5.0
11.0
10.5
14.0
82-580
92-260
62
160
WARNING
This conversion kit shall be installed by a
qualifi ed service agency in accordance with
the manufacturer's instructions and all appli-
cable codes and requirements of the authority
having jurisdiction. If the information in these
instructions is not followed exactly, a fi re, ex-
plosion or production of carbon monoxide may
result causing property damage, personal in-
jury or loss of life. The qualifi ed service agency
is responsible for the proper installation of this
kit. The installation is not proper and complete
until the operation of the converted appliance
is checked as specifi ed in the manufacturer's
instructions supplied with the kit.
Use this manual in conjunction with the instal-
lation manual supplied with the appliance.
RF24BN
RF24XBN
Natural
0–4,500 Feet
20,500
12,500
9.5
3.7
5.0
10.5
82-580
30
62
105
185
RF24BP
RF24XBP
Propane
19,000
12,500
10.5
11.0
14.0
92-200
30
125

Publicité

loading

Sommaire des Matières pour Valor Retrofire RF24DVN

  • Page 1 Gas Conversion Kits RA24NK (DV), RA24PK (DV) RA24BN (BV), RA24BP (BV) Use with Valor Retrofi re Heater Models RF24D, RF24B, RF24ID or RF24XB ONLY Installation Instructions This appliance is certifi ed for use from 0-4500ft. For WARNING altitudes above 4500ft see local codes.
  • Page 2 Conversion Procedure 4. Remove and replace the minimum rate by-pass screw from the underside of the valve. The screw 1. Remove window, ceramic logs and bricks (if has a rubber o-ring holding it into the valve body any) from fi rebox (see RF24 installation manual). and may require prying out or removing the screw 2.
  • Page 3 Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication. Designed and Manufactured by / for Miles Industries Ltd. 190 – 2255 Dollarton Highway, North Vancouver, B.C., CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfi replaces.com...
  • Page 4 Gas Conversion Kits RA24NK (DV), RA24PK (DV) RA24BN (BV), RA24BP (BV) Utilisez avec les foyers Valor Retrofi re RF24D, RF24B, RF24ID ou RF24XB SEULEMENT Directives d’installation Cet appareil est certifi é pour utilisation de 0 à 4 500 AVERTISSEMENT pieds. Pour altitudes au-dessus de 4 500 pieds, consultez la réglementation locale.
  • Page 5 Procédure de conversion 4. Enlevez et remplacez la vis d’indice minimum du dessous de la valve. La vis est maintenue en 1. Enlevez la fenêtre, les bûches et les panneaux place par un joint torique de caoutchouc. Il peut être de briques (s’il y a lieu) de la boîte de foyer (voir nécessaire de devoir forcer le joint hors de sa position le manuel d’installation du RF24).
  • Page 6 b) RF24DV ou RF24ID. À l’aide de la lame Réglez la vis de réglage de pression pendant que d’un petit tournevis ou autre objet similaire, l’appareil fonctionne à son apport maximal afi n de soulevez le capuchon de plastique couvrant la produire la pression d’admission indiquée à...