Section 1.
Important Safety Instructions
1.1

Safety Instructions

All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the
following:
RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED, CAN RESULT IN SERIOUS INJURY
OR DEATH. Do not block pump suction as this can cause severe injury or death. Do not use this pump for wading
pools, shallow pools or spas containing bottom drains, unless the pump is connected to at least two functioning
suction outlets. Suction outlet (drain) assemblies and covers must be certified to the latest published version of
ANSI
/ASME
A112.19.8, or its successor standard, ANSI/APSP-16.
®
®
To reduce the risk of injury, do not permit children to use this product.
To reduce the risk of property damage or injury, do not attempt to change the backwash (multiport, slide, or full flow)
valve position with the pump running.
Zodiac
pumps are powered by a high voltage electric motor and must be installed by a licensed or certified
®
electrician or a qualified swimming pool service technician.
RISK OF ELECTRIC SHOCK, FIRE, PERSONAL INJURY, OR DEATH. Connect only to a branch circuit that is
protected by a ground-fault circuit-interrupter (GFCI). Contact a qualified electrician if you cannot verify that the
circuit is protected by a GFCI. A GFCI should be provided by the installer and should be tested on a routine basis.
To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should
be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the
pump without the test button being pushed, a ground current is flowing, indicating the possibility of electrical shock.
Do not use the pump. Disconnect the pump and have the problem corrected by a qualified service representative
before using.
Due to the potential risk of fire, electric shock, or injuries to persons, Zodiac Pumps must be installed
in accordance with the National Electrical Code
Occupational Safety and Health Act (OSHA
Fire Protection Association (NFPA
government inspection agency.
In Canada, Zodiac Pumps must be installed in accordance with the Canadian Electrical Code (CEC).
Incorrectly installed equipment may fail, causing severe injury or property damage.
• Do not connect the system to an unregulated city water system or other external source of
pressurized water producing pressures greater than 35 PSI.
• Trapped air in system can cause the filter lid to be blown off, which can result in death, serious
personal injury, or property damage. Be sure all air is out of the system before operating.
Pro Series VS PlusHP Pumps
®
READ AND FOLLOW ALL INSTRUCTIONS
). Copies of the NEC may be ordered from the National
®
) online at www.nfpa.org or call 617-770-3000, or contact your local
®
|
Installation & Operation Manual
WARNING
WARNING
WARNING
WARNING
WARNING
(NEC
), all local electrical and safety codes, and the
®
®
WARNING
WARNING
Page 3