Page 16
ENGLISH
Symptom
Variable-Speed
Incorrect dip switch setting.
Controller LCD
Make sure pump dip switches 1 and 2
is not displaying
are both ON if the controller is the JEP-R
information
and both are OFF if the controller is a
or
PDA, AquaLink RS, or AquaLink Z4. See
pump LEDs are
"3.2.4.1 Install with AquaLink® controller"
not illuminated.
Improper low-voltage wiring.
Check low-voltage wiring between pump
and controller. Correct if necessary. See
"3.2 Electrical Installation"
Jandy
Pro Series VS PlusHP Pumps
®
Possible Cause/Solution
|
Installation & Operation Manual
Symptom
Controller
Improper low-voltage wiring.
displays "Pump
Check low-voltage wiring between pump
not connected".
and controller. Correct if necessary. See
"3.2 Electrical Installation"
Improper pump address set.
Ensure pump dip switches 3 and 4 are set
properly for the installation. Both should
be OFF for use with Variable-Speed
Controller or set to the proper address
when connected to an AquaLink RS,
AquaLink PDA, or an AquaLink Z4. See
"3.2.4.1 Install with AquaLink® controller"
Fault message
Fault condition exists.
appears on
View fault message on controller and
controller display.
correct fault before proceeding. If unsure
how to correct fault, contact Zodiac
Technical Support at 800.822.7933.
Possible Cause/Solution