INSTALLING SAFETY CABLE
2.
Find a secure attachment point (wood ceiling joist
recommended) and secure safety cable (U) using
a heavy-duty wood screw, washer and lock
washer (none included).
NOTE: Extra cable slack can be left in ceiling
area.
WIRING
WARNING: To reduce the risk of fire, electrical
shock or personal injury, wire connectors provided
with this fan are designed to accept only one
12-gauge house wire and two lead wires from the
fan. If your house wire is larger than 12-gauge or
there is more than one house wire to connect to the
corresponding fan lead wires, consult an electrician
for the proper size wire connectors to use.
CAUTION: Be sure outlet box is properly grounded
and that a ground (green or bare) wire is present.
WARNING: If house wires are different colors
than referred to in the following steps, stop
immediately. A professional electrician is
recommended to determine wiring.
1.
Choose wiring diagram (Fig. 1a, Fig. 1b or Fig. 1c)
that fits your situation and make appropriate wiring
connections as follows: [NOTE: For each wire
connection below, use one of the wire connectors
(CC), making sure to screw wire connector (CC) on
in a clockwise direction.]
1a. FAN AND LIGHT CONTROLLED BY PULL
CHAINS: Connect BLACK and BLUE wire from
fan to BLACK wire from ceiling. Connect WHITE
wire from fan to WHITE wire from ceiling. Connect
all GROUND (GREEN) wires together from fan
(on motor assembly (C) and mounting bracket (A))
to BARE/GREEN wire from ceiling.
2
Wood
Joist
FAN AND LIGHT CONTROLLED BY PULL CHAINS
FAN AND LIGHT CONTROLLED BY TWO WALL SWITCHES
1a
120 V Power
from ceiling
A
C
9
Wood Screw,
Washer and
Lock Washer
Loop
U
BLACK
BLACK
WHITE
WHITE
GROUND/GREEN (BARE)
GROUND/GREEN (BARE)
CC
GROUND/G
GROUND/GREEN
GREE
EN
WHITE
WHITE
WHITE
WHITE
WHITE
FROM FAN
FROM FAN
BLACK
BLUE
BLUE
BLUE
BLACK
BLACK
CC