Fig. 17: Pull-down clamping
Workpiece correctly clamped
Workpiece incorrectly clamped.
Risk of damage to the jaws and the workpiece.
Ø Only clamp the workpiece when lying flat.
Ø Only clamp workpieces of a suitable size.
Different clamping force for pull-down clamping.
If pull-down clamping is used, the clamping force of the NC4 - 125 is max. 30 kN and
of NC4 - 160 max. 50 kN.