4.5 Performing the radio test
The radio test allows to verify the communication between the base station and the room control
unit. The radio test must always be carried through at the planned installation location of the room
control unit.
9 The base station must not be in pairing mode for this.
¾ Start the radio test at the room control unit (see Room Control Unit Manual).
9 The heating zone allocated to the room control unit is activated for one minute, thus it is
switched off or on depending on the status of operation.
9 If there is no activation, the reception conditions are unfavourable. Proceed as follows:
¾ Taking into account the installation conditions of the room control unit, change the
installation position until you have a reception signal, or
¾ Use the optional accessories "Active antenna" or "Repeater" in order to amplify the radio
signal. You can find information on the installation in the respective manual.
DEU
4.6 System configuration
The configuration of the base station is done optionally via the microSD, the software interface of
ENG
the Ethernet variant or the Service level of the room control unit Bus Display.
FRA
4.6.1 System configuration with microSD card
NDL
Individual settings can be made via the EZR Manager SD Card under www.ezr-home.de and
transferred to the base station via the microSD card. As of software version 01.70, the base station
ITA
accepts microSD cards >2 GB in the formats FAT16 or FAT32.
ESP
¾ Open www.ezr-home.de in the web browser of your PC, select EZR Manager SD Card and
follow the instructions on-line.
¾ Insert the microSD card with the updated data into the base station.
9 The transfer process will start automatically and copy the updated data into the base sta-
tion.
9 The LED "syBUS" flashes during the transfer process.
9 After a successful data transmission, the LED "syBUS" goes out.
4.6.2 Configuration with room control unit Wireless Display
The Service level of the base station Wireless Display is protected with a PIN code and may only
be used by authorized specialists.
Attention! Faulty configuration leads to errors and damage to installations.
¾ Press the rotary control.
¾ Select the menu "Service Level" and activate by pressing.
¾ Enter the 4-digit PIN (standard: 1234) by rotating and pressing.
¾ Select parameters (PAr) by pressing again and enter the number code of the desired param-
eter (see following table).
¾ Change parameters as required and confirm by pressing.
40