6.7 Assembly/Installation
To mount the Panel:
• Remove the two screws and lift the cover.
• Fix the Panel to the boiler casing using the 4 holes provided.
ATTENTION
• The Panel must be mounted on the boiler.
• In any other case, provide adequate protection for the passage of the electrical wires and preventing access to live parts,
through the holes on the bottom of the unit.
To access the instruments, rotate the front panel (A).
To access the terminal block and unwind the thermostat and thermometer capillaries, remove the top panel (B) after removing the 2 side
screws (C).
The control thermostats (12-13 -Fig. 16) are user-adjustable by means of the front knob.
The safety thermostat has a fixed setting and manual reset as required.
80
EN
Fig. 24
cod. - Rev. 02 - 03/2018
TP3 COND