Transport
Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport it.
When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
Storage
Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.
This appliance must only be stored in inte-
rior rooms.
Maintenance and care
Danger
First pull out the plug from the mains before
carrying out any tasks on the machine.
Clean main filter basket
Main filter basket (washable), clean it
under running water if necessary.
Caution
Risk of damage! Never insert the main filter
basket while wet.
Replace exhaust filter
Exhaust filter: Change once a year
Release and remove the cover.
Remove the filter casing.
Remove the exhaust filter from the filter
housing.
Insert new exhaust filter into filter hous-
ing.
Insert filter casing.
Install and lock the cover.
Replace motor protection filter
Release and remove the suction head.
Push the grids of the motor protection
filter down, turn and remove.
Remove the motor protection filter.
Insert the new motor protection filter.
Insert the grid of the motor protection fil-
ter and lock it into place.
Insert and lock the suction head.
Troubleshooting
Danger
First pull out the plug from the mains before
carrying out any tasks on the machine.
The appliance shuts off during the
Motor thermal protector has responded.
–
Replace the fleece filter bag or paper fil-
ter bag (option).
Replace motor protection filter.
Replace exhaust filter.
Check all parts for plugging.
Switching back on after the motor turbine
has cooled off, after approx. 30 to 40 min-
utes.
Suction turbine does not run
Check the receptacle and the fuse of
the power supply.
Check the power cable and the power
plug of the device.
Turn on the appliance.
Suction capacity decreases
Remove choking of suction nozzle, suc-
tion tube or suction hose.
Replace the fleece filter bag or paper fil-
ter bag (option).
Clean the main filter basket under run-
ning water.
Insert/lock the suction head correctly.
Replace defective suction hose.
Replace motor protection filter.
– 3
EN
operation
11