LED Display
FC
Photocell1
FD
Photocell2
FE
Buzzer Function
FF
Reverse Impulse for
Electric Lock
FG
Open/Stop/Close/Stop
Function key
FH
Pedestrian Mode Function
key
FI
Auto-Close Function key
Note (Parameter F3)
Please set F3 Function after system learning. The LED display 10 to indicate all of the recorded values will increase 1 ampere as
the over current value. In other words, the LED shows 20 to indicate all the recorded values will increase 2 ampere as the over
current value. The value can be adjusted by pressing button UP and DOWN. The maximum value is 40(4.0A) and the minimum
value is 05 (0.5A)
8
Complete programming chart (2)
Definition
Parameter
FC-0
FC-1
FD-0
FD-1
FE-0
FE-1
FF-0
FF-1
FG-1
FG-2
FG-3
FG-4
FH-0
FH-1
FH-2
FH-3
FH-4
FI-0
FI-1
FI-2
FI-3
FI-4
Mode
1. The factory setting is "FC-0".
OFF
ON
OFF
1. The factory setting is "FD-0".
ON
OFF
1. The factory setting is "FE-0".
ON
OFF
1. if the Function is on, the gate will move forward a
little before the gate operate for releasing the Latch
ON
2. The factory setting is "FF-1".
A key
1. The factory setting is "FG-1".
B key
C key
D key
OFF
1. The factory setting is "FH-2".
A key
B key
C key
D key
OFF
1. The key is to turn on or off the Auto-Close Function.
2. The factory setting is "FI-3".
A key
3. When the flasher and buzzer is running, the auto
B key
closed button has no Function till flasher and buzzer
C key
finish running.
D key