B.2
Technical data
Nominal capacity
Outer diameter of the cylinder
(without heat insulation)
Outer diameter of the cylinder (with
heat insulation)
Height (incl. purging valve)
Height (incl. purging valve + heat in-
sulation)
Net weight
Total weight
Connections
Material of the cylinder and the con-
nections
Operating pressure
Maximum operating temperature
Standby energy consumption
C

allSTOR buffer cylinder system

This section describes examples of how the allSTOR buffer cylinder can be integrated into various systems.
Danger!
Risk of death caused by incorrect installation of the system
An incorrectly installed system may cause both personal injury and material damage.
Plan the system in accordance with the regulations of the country in which the system is to be in-
stalled.
Request the planning information from the manufacturer.
C.1
System description
The allSTOR buffer cylinder system can be used to operate:
Heating installations with domestic hot water generation
Pure heating installations (no domestic hot water generation)
Pure domestic hot water installations (no heating)
either with or without solar support.
The buffer cylinder system consists of a buffer cylinder and at least one other component. The following buffer cylinders and
components are available:
Buffer cylinder
VPS 800
VPS 1000
VPS 1500
VPS 2000
Domestic hot water station, either with or without a circulation pump
VPM 60/3 W Fix Pump
VPM 90/3 W Fix Pump
VPM 135/3 W Fix Pump
VPM 45/3 W Mod Pump
VPM 60/3 W Mod Pump
VPM 90/3 W Mod Pump
VPM 135/3 W Mod Pump
VPM 180/3 W Mod Pump
28
VPS 800/4-5
VPS 1000/4-5
773 l
961 l
790 mm
790 mm
1,070 mm
1,070 mm
1,846 mm
2,226 mm
1,944 mm
2,324 mm
117 kg
132 kg
890 kg
1,093 kg
R 2"
R 2"
Steel
Steel
0.1 ... 0.6 MPa
0.1 ... 0.6 MPa
(1.0 ... 6.0 bar)
(1.0 ... 6.0 bar)
95 ℃
95 ℃
< 2.4 kWh/24 h
< 2.5 kWh/24 h
Installation and maintenance instructions allSTOR plus 0020314387_00
VPS 1500/4-5
VPS 2000/4-5
1,496 l
1,907 l
1,000 mm
1,100 mm
1,400 mm
1,500 mm
2,205 mm
2,330 mm
2,362 mm
2,485 mm
207 kg
242 kg
1,703 kg
2,149 kg
R 2 1/2"
R 2 1/2"
Steel
Steel
0.1 ... 0.6 MPa
0.1 ... 0.6 MPa
(1.0 ... 6.0 bar)
(1.0 ... 6.0 bar)
95 ℃
95 ℃
< 2.9 kWh/24 h
< 3.3 kWh/24 h