3.4.1 Replace Blue Pressure Test O-ring if
If you open the pump lid before conducting the
pressure test, the blue o-ring will probably fall out. If
this happens, you will need to install it on the lid again
before conducting pressure testing.
There is a risk of damage to the blue o-ring during
re-installation. If you damage it when trying to re-install
it, you will need to order a new blue pressure test o-ring
before you begin conducting the pressure test.
These instructions describe the proper procedures
for replacing, using, and disposing of the blue o-ring.
These instructions must be followed exactly. Read
through the instructions completely before starting the
procedure.
3.4.1.1
1.
Make sure that the pump is turned off.
2.
Make sure that the switch to the circuit breaker
that powers the pump motor is turned off.
Turn off the pump and the main breaker in the pump
electrical circuit before starting the procedure. Failure
to comply may cause a shock hazard, resulting in
severe personal injury or death.
Due to the potential risk of fire, electric shock, or
injuries to persons, Jandy Pro Series Pumps must be
installed in accordance with the National Electrical
Code
®
and the occupational Safety and Health Act (OSHA).
Copies of the NEC may be ordered from the National
Protection Association, 470 Atlantic Ave., Boston,
MA 02210, or from your local government inspection
agency.
In Canada, Zodiac Pumps must be installed in
accordance with the Canadian Electrical Code
(CEC).
3.
Make sure all necessary isolation valves are closed
to prevent pool water from reaching the pump.
4.
Following the markings on the locking ring, turn
the ring counter-clockwise until the 'START'
markings align with the ports.
5.
Carefully remove the lid with locking ring.
Necessary

Remove Pump Lid

WARNING
ELECTRICAL SHOCK HAZARD
WARNING
ELECTRICAL SHOCK HAZARD
(NEC
), all local electrical and safety codes,
®