Adjustments; Lubrication - Southbend TruVection TVGS-12SC Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

A
DJUSTMENTS
A
DJUSTMENTS
ADJUSTMENTS AND SERVICE WORK MAY BE PERFORMED ONLY BY A QUALIFIED
TECHNICIAN WHO IS EXPERIENCED IN, AND KNOWLEDGEABLE WITH, THE OPERATION OF
COMMERCIAL COOKING EQUIPMENT. HOWEVER, TO ASSURE YOUR CONFIDENCE,
CONTACT YOUR AUTHORIZED SERVICE AGENCY FOR RELIABLE SERVICE, DEPENDABLE
ADVICE OR OTHER ASSISTANCE, AND FOR GENUINE FACTORY PARTS.
Warranty will be void and the manufacturer is relieved of all liability if service work is performed by
other than a qualified technician, or if other than genuine Southbend replacement parts are installed.

LUBRICATION

The door chains and sprockets have been lubricated at the factory with high temperature "Never Seeze"
lubricant. After each six months of usage, lubricate the door chains and sprockets with the same type of
lubricant.
Motor lubrication information can be found on permanent label located on motor.
Casters are provided with a fitting for proper lubrication when required.
ADJUSTING GAS PRESSURE REGULATOR
The pressure regulator is factory set at 6" W.C. for natural gas and 10" W.C. for propane gas. To check the
manifold pressure:
1. Turn the power switch to the "OFF" position.
2. Turn main gas valve to entire unit off.
3. Remove the lower panel and locate 1/8" plug in manifold.
4. Remove plug and install a fitting appropriate to connect a manometer.
5. Turn on main gas to unit and turn on power switch.
6. When the burners light, read manometer.
7. If manometer does not read 6" W.C. for natural gas, or 10" W.C. for propane gas, adjust regulator (if
gas pressure is O.K. go to Step 10).
8. Remove cap from top of regulator.
9. With a screwdriver rotate regulator adjustment screw clockwise to increase, or counterclockwise to
decrease, pressure until manometer shows correct reading.
10. Repeat steps 1 and 2.
11. Remove manometer fitting and replace plug in manifold.
12. Turn on main gas to unit, turn on power switch, and check that new plug in manifold does not leak.
13. Replace lower panel.