PNEUMATIC GUN FOR 370mm CARTRIDGES AND BAGS
If the piston assembly tends to rotate, use a slotted screwdriver inserted in the spokes of
the blue scraper to adjust.
Setting recovery
Disconnect or shut off the machine from the air supply, turn the front ring nut (2) anti-clockwise
and remove from the gun.
Extract the cartridge from the material holder tube (7).
For safety purposes, refi t the front ring nut (2) turning it clockwise through two turns only, then
turn the pressure regulator anti-clockwise to the end of its stroke; connect the machine to the air
supply, keeping the trigger pressure and then gradually unscrew the regulator clockwise until the gun
and adaptor move forward; when these elements reach the front ring nut, shut off or disconnect the
air supply.
Turn the front ring nut anti-clockwise.
Remove the adaptor with care.
Use a 5 mm Allen key to to screw on the bag pressing cone clockwise, tighten it fully down avoid
excessive pressure.
Turn the front ring nut (2) clockwise.
For connection to the pneumatic air feed
Before using the gun, always check:
The opening of the feeding system air fl ow regulator.
The opening of the pressure regulator on the gun.
See preceding chapter for bag or cartridge refi ll.
Use the control lever to activate the gun and start working.
Disconnect the air feed to stop using the gun; if some material is left inside the cartridge, close it at
the front to avoid product dry up.