Problem Solving; Technical Specifications - Wetrok Discomatic Samba XT Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13

Problem solving

FAULT
Machine does not work
Cleaning action inadequate
No suction or suction inadequate
Streak formation
No supply of cleaning agent or water,
or supply inadequate
Batteries not charged or
charge is too low
Technical specifications
Discomatic Samba XT
Nominal voltage
Theoretical power
Operating width
Width of suction nozzle, folded
Fresh water tank
Dirty water tank
Brush motor
Suction turbine
Valve
Overall nominal rating
Battery capacity
Duration of battery charge
Weight without battery, without water
CAUSE
Fuse
Power interrupted
Brush / pad badly worn
Dosing too low
Recovery tank not attached correctly
(sealing for suction turbines)
Suction nozzle clogged
Suction hose not connected
Tank lid not closed or seal defective
Sealing lid at outlet hose not correctly screwed on or
seal faulty
Turbine at OFF
Suction lips contaminated or worn
Incorrect angle setting for suction nozzle
Tubes clogged
Fresh water valve clogged
Valve at OFF
No fresh water in tank
Duration of battery charging too short
End of battery service life reached
V
24V DC
m2/h
900-1200
mm
380
mm
460
l
15
l
23
W
250
W
300
W
6.5
W
557
Ah
25
h
max. 1
kg
40
33
SOLUTION
Change fuse
Check connections
Replace brush / pad
Turn up dosing
Attach recovery tank correctly
Remove clogging
Connect suction hose
Close tank lid correctly or replace seal
Check seal, screw on lid firmly,
replace if necessary
Set turbine to ON position
Clean or replace suction lips
Set angle of suction nozzle correctly
- Center wheel 3 mm ground clearance
- Side wheels 0 mm ground clearance
Rinse fresh water tank and tube system
with clean water
Clean fresh water valve
Set valve ON (regular 45°)
Fill with fresh water
Observe the required charging duration
Change batteries (observe safety instructions)
Weight with battery 25 Ah
Weight: battery+water
Max. dimensions (LxWxH)
Underclearance
Suction turbine
Brush pressure
Brush pressure
Brush rpm
Noise level (DIN)
Max. permissible incline
Anti-splash protection
Certification mark:
kg
62
kg
77
mm
910 x 500 x 1110
mm
630
mbar
90
N/cm2
0.30 – 0.41
kg
20 – 28.5
1/min.
130
dB (A)
71
%
2
IP..
IP X4
CE
EN

Publicité

Table des Matières
loading

Table des Matières