Advanced Z Wave temperature and humidity reporting
This thermostat may be configured to report the actual room temperature in
a higher resolution than can be shown on the thermostat display. The default
temperature reporting resolution is 1 °F or 0.5 °C. When configured to ADVANCED,
the temperature reporting resolution will be 0.5 °F or 0.25 °C. To change default
temperature reporting to a higher resolution, go to thermostat MENU/Z-WAVE
SETUP/TEMP REPORT and set to ADVANCED. The temperature is reported by
every displayed value change, and no later than 2 hours from last report.
The thermostat can be configured to report changes in temperature less frequently.
This is recommended to increase battery life when the thermostat does not use a
common wire (C wire). Available setting range is 1-5 °F (default normal 1 °F).
NOTE: When higher temperature resolution reporting is set, you may experience
different resolution of temperature displayed on the thermostat and Z-Wave
controller.
Humidity Reporting
The thermostat can be configured to report changes in humidity less frequently.
This is recommended to increase battery life when the thermostat does not use a
common wire (C wire). Available setting range is 1% RH 5% RH (default 1% RH). To
access this setting, go to thermostat MENU/Z WAVE SETUP/HUM REPORT.

Z-Wave connection status

Z-Wave connection status is located in the upper-right corner of the screen.
• Thermostat is included and connected to a Z-Wave network.
• Thermostat is excluded from a Z-Wave network.
• Thermostat is either included in a Z-Wave network but the Z-Wave signal
is lost, or is included but AC power is lost (battery used as backup). In this
case, Z-Wave radio is turned off to preserve battery life. AC power must be
restored or you have to change the power mode. It can be done via excluding
thermostat from Z-wave network and including again in battery power mode
where batteries are used as main power source. You can check the actual
power mode in the thermostat MENU/DEVICE INFO.