ISU Options (defaults in bold)
425
Adaptive Recovery
On, Off
430
Minimum Cool
50 °F to 99 °F (50 °F); 10.0 °C to 37.0 °C (10.0 °C)
Setpoint
431
Maximum Heat
40 °F to 90 °F (90 °F); 4.5 °C to 32.0 °C (32.2 °C)
Setpoint
435
Lock Screen
None, Partial, Full
500
Indoor Sensor
Yes, No
515
Sensor type
10k, 20k
520
Temperature Control
Thermostat, Wired, Average
0 - 2
702
Air Filters
711
Air Filter 1 Reminder
Off
10, 20, 30, 45, 60, 90, 120, 150 Run Time Days
30, 45, 60, 75 Days
3, 4, 5, 6, 9, 12, 15 Months
712
Air Filter 2 Reminder
Off
10, 20, 30, 45, 60, 90, 120, 150 Run Time Days
30, 45, 60, 75 Days
3, 4, 5, 6, 9, 12, 15 Months
810
Hum Pad Reminder
Off
6, 12 Calendar Months
921
Dehum Filter
Off
Reminder
30, 60 Calendar Days
3 - 12 Calendar Months (in 1 month increments)
1018
Vent Filter Reminder
Off, 3, 6, 9, 12 months
Notes
Adaptive Intelligent Recovery (AIR) is a comfort setting. Heating or cooling equipment will turn on earlier,
ensuring the indoor temperature will match the setpoint at the scheduled time.
The user cannot set the cooling temperature below this level.
The user cannot set the heating temperature above this level.
Unlocked: User has access to all thermostat settings.
Partially Locked: User can modify only temperature settings.
Fully Locked: User cannot modify any settings. Screen will be locked by default factory code and cannot be
changed. This code is displayed for a short time, when you are about to lock the thermostat screen. Please note
the code in safe place for future reference.
Set this ISU when you want to wire a remote indoor sensor to the "S" terminals on the UWP - see "Wiring termi-
nal designations" on page 5. This ISU is only displayed only if ISU 130 is set to NO wired outdoor sensor
configured.
Choose resistance type of wired indoor sensor. This ISU is only displayed when indoor sensor is configured -
ISU 500.
This ISU is only displayed when indoor sensor is configured - ISU 500. You can choose what temperature
source to be used or you can ask thermostat to use both thermostat and remote sensors for higher accuracy of
measurement.
This ISU refers to the number of air filters in the system.
Choose either calendar or equipment run time-based reminder.
Choose either calendar or equipment run time-based reminder.