From Top menu
LAST FULL CHARGE
10 DAYS AGO
LAST EQUALIZE
22 DAYS AGO
MAX BAT VOLTS
15.4V
CLR►
MIN BAT VOLTS
11.9V
CLR►
TOTAL CHG AMP-HR
+1980AH
CLR►
LIFETIME BAT AH
-9876543AH CLR►
BAT TEMPERATURE
25C
77F
VIEW CHARGE UNIT
STATUS
SEL►
ENTER SETUP
MENUS
SEL►
Controller address #0 – 7. NEXT scrolls through each
controller status screen. BACK returns to Advanced Display
menu.
* Screen will be blank except for address if controller not
communicating on network.

ADVANCED DISPLAY Menu

Days since last full charge or equalize. The equalize day counter resets upon
commencing equalize.
Day counter accuracy is +1 / -0 days as day counter transitions occur following
each 24 hour period from when battery power was applied. Consider applying
battery power late in the evening to improve counter accuracy. Maximum range is
255 days which is also shown if days are unknown.
Captures minimum and maximum battery voltage since last cleared.
Captures total output amp-hours of all charge controllers on the IPN network since
last cleared.
Serves as battery "odometer" capturing total discharge amp-hours since last
cleared. Value saved to non-volatile memory once per day.
Shows present battery temperature if optional sensor installed on charge
controller.
Selects status display of controllers on IPN network.
Internal temperature *
To Setup menus
if selected.
FIGURE 3
Installation and Operation Manual
0 +25C OUT 12.3A
IN 17.5V
12.0A
7 +29C OUT 14.5A
IN 18.5V
15.0A
PV Input voltage *
Output current *
PV Input current *
6