From Setup menu
SET ACCEPT CHG
14.4V
SEL►
SET FLOAT CHG
13.4V
SEL►
SET EQUALIZ CHG
15.2V
SEL►
SET EQUALIZ TIME
2.0HRS
SEL►
SET AUTO EQUALIZ
30DAYS
SEL►
SET T-COMP SLOPE
-5.00mV/C/C SEL►
SET FLOAT CURENT
1.5A/100AH SEL►
SET ACCEPT TIME
2.0HRS
SEL►
BATTERY CHARGE PARAMETERS Menu
Sets Acceptance charge voltage setpoint.
Range 10.0 to 80.0V.
Sets Float charge voltage setpoint.
Range 10.0 to 80.0V.
Sets Equalize voltage setpoint.
Range 10.0 to 80.0V.
Sets Equalize time.
Range 0.5 to 10 hours.
Sets days between automatic Equalize. Range is 10 to 400 days. Fully MANUAL
equalization is selected by a setting of less than 10 days.
Sets charge voltage temperature compensation factor. Range is -0.00 to -
8.00mV/°C/cell.
Sets Float Transition Current. Range 0.1 to 10.0A per 100 AH. A setting of 0 (zero)
disables function such that full charge is based on acceptance charge time only.
See charge controller operators manual.
Sets Acceptance charge time.
Range 0.0 to 10.0 hours.
FIGURE 5
Installation and Operation Manual
8