SET BAT AMP-HRS
220AH
SET CHG EFICENCY
94%
SET CHGEFCY MODE
AUTO ADJUST SEL►
SET SELF-DISCHG
12%/MONTH
SET MAXIMUM BAT
VOLTS 15.5V SEL►
SET AUX OUT MODE
BAT VOLTS
SET AUX OUT OFF
<
11.5V
SET AUX OUT ON
>
12.6V
POST-DUSK LIGHTS
ON 2.5 HRS
PRE-DAWN LIGHTS
DISABLED
SET BACK-LIGHT
AUTO
RESET CURRENT
SHUNT ZERO
RESTORE DEFAULT
SETINGS
SET BAT CHARGE
PARAMETERS
7
From Advanced Display menu
SEL►
SEL►
SEL►
SEL►
SEL►
SEL►
SEL►
SEL►
SEL►
SET►
SET►
SEL►
To Battery Charge Parameters menu
if selected.

SETUP Menu

Total battery amp-hours at 25°C, 20hr rate.
With charge efficiency set to 94%, battery is expected to retain 94 amp-hours for
each 100 amp-hours of charge. With charge efficiency mode set to FIXED, charge
efficiency value remains as set. If set to AUTO ADJUST it automatically adjusts
based on actual charge efficiency to continuously improve remaining battery
capacity accuracy.
Self discharge rate in percent per month at 25°C.
Maximum charge voltage setpoint limit regardless of other settings or temperature
compensation.
Sets IPN Master charge controller "load control" mode to be based on battery
VOLTS or battery AMP-HOURS. Setting units (V or AH) in setting screens change
based on present mode setting.
Note: Be certain to set voltage settings even if using amp-hour control as the
charge controller will default to voltage control if battery amp-hours are
unavailable.
Enables, disables and sets ON time for lighting control mode. Lighting control
mode is disabled if BOTH Post-Dusk and Pre-Dawn timers are set to DISABLED
(<0.5 hrs). Lighting control mode is enabled if EITHER Post-Dusk or Pre-Dawn
timers are set to a time value. See charge controller operators manual.
Sets display backlight to ON, OFF or AUTO. In AUTO, backlight remains ON for
one minute following last key press.
Corrects for "zero offset" in net battery current display.
CAUTION: Be certain shunt signal is a true zero before performing this function or
inaccurate battery current & amp-hour readings will result. See Resetting Current
Shunt Zero section of manual before proceeding!
Restores all factory default settings in the IPN-ProRemote and charge controllers,
except for auxiliary output settings in slave controllers. Only the Master's auxiliary
output settings are available over the IPN network and are restored.