Removable internal sections
1 03.76177.000
baffle plate
2 03.77510.100
vermiculite inner plate side
3 03.77416.002
log retainer side glass left
4 03.05403.120
ash removal port
5 03.77419.002
fire basket
6 03.77511.100
vermiculite inner plate rear
7 03.77417.002
log retainer side glass right
bottom of the fire
8 03.66538.000
compartment
(missing or bad snippet)
An optional heat shield is available. By using this
heat shield you can reduce the distance to the
combustible material. See appendix "Distance
from combustible material". The heat shield (1) is
hooked onto the rear wall and affixed with a screw
(3). For a rear connection the escape plate (2)
needs to be removed; see following figure.
8
Connect to rear
1. Apply supplied fibre glass sealing tape (2)
measuring 10 x 3 mm to the connection collar's
contact surface (6).
2. Fit the connection collar to the back wall using the
materials supplied (4), (5) and (7).
3. Apply supplied fibre glass sealing tape (2)
measuring 10 x 3 mm to the contact surface of the
cover (1).
4. Fit the cover to the inner top plate with the
materials supplied (3).
Following correct placement to the upper side,
the cover is designed to form a whole with the
top plate. The cover has been correctly placed
if the space in the lower edge of the cover falls
into the slot in the inner top plate.
Subject to change because of technical improvements