3.3. Red light indicates faults
3.3.1. when trigger is pressed
Causes
– Tool not in front position
3.3.2. while pulling the rivet
Causes
– Overloading
– Overheating of electronic control
– Battery empty
3.3.3. after releasing the trigger
Causes
– Jaw assembly does not reach the front
position
3.3.4. Note
– In case of trouble indicated by the red light, which can't be eliminated as described above, the tool has
to be repaired by trained personnel only or to be returned to the distributor or the manufacturer.
4. Warranty
This riveting tool has a 24 months warranty from the day of delivery (to be proved by invoice or
delivery note). Damage caused by common wearing, overloading or improper handling are excluded
from the warranty.
Damages caused by material or manufacturing faults will be covered by this warranty and will be re-
paired or replaced at no cost. Claims can only be accepted if the complete riveting tool (not stripped)
is returned to the distributor or GESIP .
5.
Conformity declaration
We hereby declare under our sole responsibility that these products meet following standards and
directives:
•
EN 50260
•
EN 60335
•
2006/42/EG
•
2006/95/EG
•
2004/108/EG
14
Remedy
release the trigger
Remedy
check working capacity according to table 1.4.
allow the tool to cool off in air
charge or replace
Remedy
screw on the jaw assembly tightly
(see 1.8. and 3.2.)
H.U. Harder
(Safety Officer)