Enables or disables start at decreased speed.
On: Executes start ups at decreased speed for 2 seconds to then shift to normal
SOFT
speed.
Off: Start at decreased speed not active.
Selects the operating mode of the blinking light during the time TCA
LTCA
On: Blinking light on during TCA
Off: Blinking light off during TCA
Enabled or disables HOLD-TO-RUN function
On: HOLD-TO-RUN function.
The pressure of the OPENS/CLOSES button must be maintained throughout the
htr
entire manoeuvre. The opening of the STOP input stops the motor. All the safety
inputs are deactivated, except for the Limit switch inputs /SW01/SW02/SWC1/
SWC2).
Off: Automatic/semiautomatic function
The operating mode with 1 or 2 motors is selected:
On: The motor operation is synchronised. This function must be used in the fol-
lowing cases:
- for each single motor, connect it to M1: Terminals 1/2.
- for two synchronised motors (e.g. balancing doors), connect one motor to M1:
1mot
terminals 1/2 and the other to M2: terminals 3/4. Adjust the parameters related
to motor 1, the M2 limit switch inputs are deactivated. TDMO and TDMC must
be 0.
Off: For two non-synchronised motors, e.g. overlapping gate leaves, adjust TDMO
and TDMC on the desired values.
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
Cvar
Off: Receiver enabled for rolling-code and programmable code transmitters (self-
learning and Dip Switch).
Selects the type of electric lock used.
On: Magnetic electric lock, normally fed at 12Vdc.
Power is cut off to the electric lock output before each opening and closing
mloc
operation.
Off: Electric lock with latch, normally not fed.
Before each opening manoeuvre power is fed at 12Vdc for the time set by the
parameter TLOC.
Activates or deactivates the push in closing function. Only with logic SLD:ON
On: The last second of the manoeuvre in closing phase is carried out at normal
BB
speed (disabling slowing) to favour a better hook of the electric lock.
Off: Function disabled.
Enables or disables the second radio channel on terminals 29/30.
2ch
On: Exit 29/30 configured with function as second radio channel.
Off: Exit 29/30 takes on function of service light (see parameter TLS).
Enables or disables checking of photocells on PHOT input, active both in closing
and in opening.
TST1
On: Check enabled. If the check has a negative result, no manoeuvre is com-
manded. See Fig.3 - "PHOTO TEST".
Off: Checking of photocells disabled at each manoeuvre.
Enables or disables checking of photocells on PHOT inputs, active only in clos-
ing.
TST2
On: Check enabled. If the check has a negative result, no manoeuvre is com-
manded. See Fig.3 - "PHOTO TEST".
Off: Checking of photocells disabled at each manoeuvre.
Enables or disables motors check.
On: Check enabled. If the check has a negative result, no manoeuvre is com-
TSTm
manded.
Off: Check disabled.
(Enables or disables remote radiotransmitters learning, as indicated in the para-
graph "Remote transmitters learning".
rem
On: Remote learning enabled.
Off: Remote learning not enabled.
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)