Lamp information

The lamps listed below are those that are installed as standard equipment at the factory . These standard lamps have been selected for
optimal tanning results and to match the UV classifi cation of your tanning appliance . We recommend that when you replace a lamp you
only use lamps of the type currently installed in your tanning appliance and which are listed in the table below and on the identifi cation
plate . If you choose to install a diff erent type of lamp, you must only use lamps that are marked with an equivalent code which indicates
that the UV component falls within the equivalence range listed on the identifi cation plate .
Note: The equivalent code is only applicable to low-pressure fl uorescent lamps .
Lamps
maxlight L 100W-R CE III
maxlight L 100W-R High Intensive
maxlight L 160W-R CE 0,3
maxlight L 180W-R High Intensive
Note: The total erythema is limited to 0 .3 W/m² for all UV types within the EU .
Model
: XXXXX
Type
: XXXXXXXX
Serial number
: XXXXXXXXXX / 3
Rated voltage
: XXXXXXXX
Rated power input
: XXX W
28 x maxlight L 180W-R High Intensive
180-R-(97-129)/(8,1-10,9)
Ballast: 160W
UV type 3 (Total Erythema output limited at 0,3W/m
Manufactured by:
VDL Hapro bv.
PO Box 73
4420 AC Kapelle, Netherlands
4
Art nr
equivalent code
12806
100-R-(22-29)/(2,7-3,7)
12808
100-R-(46-61)/(5,8-7,8)
35378
160-R-(29-38)/(2,1-2,9)
22796
180-R-(97-129)/(8,1-10,9)
Example:
On the example identifi cation plate shown the equivalent codes for the installed lamps are circled .
The equivalent code is 180-R-(97-129)/(8,1-10,9)
180 =
the wattage of the lamp
R =
the refl ector type
(97-129) = the equivalence range for the total eff ective erythema
(8,1-10,9) = the equivalence range for the NMSC ratio
Warning!
When it is necessary to replace the UV lamps, we recommend the use of original lamps of the type
prescribed on the identifi cation plate . The use of other lamps increases the risk of technical problems with
the appliance that are not covered by the warranty . If you choose to replace lamps with non-original UV
lamps that have a matching equivalence code, it is important that you use lamps with identical technical
specifi cations .
3
)
Warning!
The use of non-original VDL Hapro high-pressure lamps for facials will result in a danger of overheating or
other technical problems . The appliance might be damaged . Please consult the identifi cation plate on the
appliance to determine which original VDL Hapro lamps are required .
UV type
3
5
2
5