General Information; Rates And Effi Ciencies - Continental Fireplaces CDVS280-1 Manuel D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Customer:
Address:
Date of Installation:
Location of Appliance:
Installer:
Dealer/Distributor
Contact Number:
Serial #:
Model:
Natural Gas:
CDVS280-1NSB
CS280-1N
CDVS280-1NE
CS280-1NE

1.0 general information

When the appliance is installed at elevations above 4,500 ft (1372m), and in the absence of specifi c recommendations
from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each
additional 1,000 ft (305m).
Change in fl ame appearance from "HI" to "LO" is more evident in natural gas than in propane. Expansion /
contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance may be installed in an aftermarket permanently located, manufactured mobile home, where not
prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certifi ed kit is used.
note:
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance and
must be installed.
This appliance is approved for bedroom and bed-sitting room installations.
The protective wrap on plated parts is best removed when the assembly is at room temperature but this can
be improved if the assembly is warmed, using a hair dryer or similar heat source. The protective wrap must be
removed before operating the appliance.
Vented decorative gas appliance: not a source of heat; not for use with solid fuel.
1.1
rates and effi ciencies
Altitude (FT)
Max. Input (BTU/HR)
Max. Output (BTU/HR)
Min. Inlet Gas Supply
Pressure
Max. Inlet Gas Supply
Pressure
Manifold Pressure
(Under Flow Conditions)
* Max. inlet pressure not to exceed 13".
Installer, please fi ll out the following information:
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
CDVS280-1
NG
30,000
25,500
4.5" (11mb) Water
Column
7" (17mb) *
Water Column
3.5" (9mb)Water
Column
Propane:
CDVS280-1PSB
CS280-1P
CDVS280-1PE
CS280-1PE
P
0-4,500
26,000
22,360
11" (27mb)
4.5" (11mb) Water
Water Column
Column
13" (32mb) Water
7" (17mb)
Column
Water Column
10" (25mb)
3.5" (9mb)Water
Water Column
Column
standard checklist
CS280-1
NG
P
30,000
26,000
24,600
21,600
11" (27mb)
Water Column
13" (32mb) Water
Column
10" (25mb)
Water Column
W415-2340 / C / 02.08.21
EN
5

Publicité

Table des Matières
loading

Table des Matières