Customer:
Address:
Date of Installation:
Location of the appliance
Installer:
Dealer/Distributor contact number:
Serial #:
Model:
Natural Gas:
CBL36NTE-1
CBL46NTE
1.0 general information
When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specific recommendations
from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each
additional 1,000ft (305m). Expansion / contraction noises during heating up and cooling down cycles are normal
and are to be expected. Change in flame appearance from "HI" to "LO" is more evident in natural gas than in
propane.
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is certified for mobile
home installation.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified kit is used.
note:
The protective wrap on plated parts is best removed when the assembly is at room temperature but this can be
improved if the assembly is warmed, using a hair dryer or similar heat source.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance
and must be installed.
This appliance is a decorative product. It is not a source of heat and not intended to burn solid fuel.
Batteries must be disposed of according to the local laws and regulations. Some batteries may be
recycled, and may be accepted for disposal at your local recycling center. Check with your
municipality for recycling instructions.
1.1
rates and efficiencies
Fuel Type
Les piles doivent être mises au rebut conformément aux lois et à la réglementation locales.
Altitude (FT)
Certaines piles peuvent être recyclées et acceptées dans votre centre de recyclage local. Rensei-
Max. Input (BTU/hr)
gnez-vous auprès de votre municipalité au sujet des directives de recyclage.
Min. Input (BTU/hr)
P4
Min. Inlet Gas Supply
Pressure
Max. Inlet Gas Supply
Las baterías deben desecharse de acuerdo con las leyes y regulaciones locales. Algunas baterías
Pressure
pueden reciclarse, y es posible que su centro de reciclado local las acepte para desecharlas.
Manifold Pressure (Under
Consulte en su municipalidad sobre las instrucciones para el reciclado.
Flow Confictions)
Installer: please fill out the following information
Propane:
CBL36-1
Natural Gas
0-4,500
17,500
12,000
44.1%
4.5" w.c. (11mb)
11" w.c. (27mb)
13" w.c. (32mb)
13" w.c. (32mb)
3.5" w.c. (9mb)
10" w.c. (25mb)
standard checklist
CBL36PTE-1
CBL46PTE
Propane
Natural Gas
0-4,500
0-4,500
16,000
24,000
12,500
17,000
45.5%
48.5%
4.5" w.c. (11mb)
13" w.c. (32mb)
3.5" w.c. (9mb)
CBL46
Propane
0-4,500
24,000
17,000
48.5%
11" w.c. (27mb)
13" w.c. (32mb)
10" w.c. (25mb)
W415-1706 / C / 04.12.18
EN
5