Cleaning and maintenance
34/64
7.7
Instructions for replacing the UV high
pressure lamps and filter panels
The UV effect of the lamps and thus the tanning effect decreases over the
course of time. Therefore, the replacement intervals specified in the mainte-
nance plan must be adhered to.
UV filters are utilized in order to control the UV radiation, e.g. the filter panels
on the facial tanner. However, the filter effect decreases over the course of
time. Therefore, the replacement intervals specified in the maintenance plan
must be adhered to.
WARNING!
Danger of burns from hot lamps and device parts!
If the tanning device was operated before being switched off
and opened, lamps and housing parts may be hot.
Before replacing lamps or other spare parts, wait until
lamps and metal parts of the device have cooled down
sufficiently.
DANGER!
Fire hazard due to overheated lamps!
Non-approved high pressure lamps can explode. Hot lamp
components can set other parts on fire. People can be killed
or severely injured due to smoke inhalation and fire.
Only fit the high pressure lamps specified by the manu-
facturer.
Clean the inside of the device regularly. Dust particles
are flammable!
Replace faulty lamps immediately.
7.7.1

Open lamp banks

WARNING!
Risk of breakage and scratching!
Acrylic glass panels can be damaged.
Never open several banks simultaneously.
NOTE:
The UV high pressure lamps and filter panels of lamp banks
A - E are cleaned and exchanged in the same way.

Publicité