Additional requirements for outdoor installation
●
Make sure to set up the spa on a firm, level and smooth surface that is strong enough to support the full
weight of the filled spa and maximum occupants.
●
Do not set up the spa on grass or dirt, as this increases the amount of debris entering the spa, and
damage the spa floor.
●
Do not leave the spa tub exposed to direct sun light for extend period of time.
●
It is possible to install and leave the spa outside at a temperature not lower than 4°C(39°F) and the water
inside the circulation system, pump, pipe are not frozen. Put a Heat Preservation Mat in between the spa
bottom and the ground to prevent heat loss from the bottom of the spa and to provide better heat retention.
PRCD Testing
Risk of electric shock: This product is provided with a PRCD located at the end of the power cord. The
PRCD must be tested before each use. Do not use the spa if the PRCD does not function properly.
Disconnect the power cord until the fault has been identified and corrected. Contact a licensed electrician to
correct the fault. There are no serviceable parts inside the PRCD. Opening the PRCD will void the warranty.
1. Plug the machine into the mains.
2. Press the RESET button on the PRCD. The indicator turns red.
3. Press the TEST button on the PRCD. The red color shown on the indicator should disappear. Otherwise the
PRCD is faulty. Do not use the spa. Contact a qualified electrician to correct the fault.
4. Press the RESET button on the PRCD again. The indicator should turn red. If yes, the spa is ready for use.
1.
Spa Control Unit Connected External Equipotential Bonding Conductors
A qualified electrician shall wire the spa control unit to the household equipotential terminal using a minimum
1.5mm² solid copper conductor.
!
WARNING
2.
RESET
RESET
TEST
Indicator
11
3.
RESET
TEST
TEST