Softswitch128 (Xps) - Lutron Softswitch128 Guide D'installation

Masquer les pouces Voir aussi pour Softswitch128:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 61
Panel Model Number Guide
Softswitch128
Feed-Through Model Numbers
Example
X P S 2 4 - 1 2 0 F T- C G P _ _ _ _
Number of Circuits
in Panel
Feed
Voltage
Number of Circuits in Panel
Indicates number of switching circuits in the panel:
8, 12, 16, 20, 24, 28, 32, 36, 40, 44, or 48
Feed Voltage
1, 2
Omit for dual voltage
120 for 120 V
230 for 230 V
(CE)
240 for 220-240 V
(non-CE)
277 for 277 V
Load Circuit Rating
16 A per circuit
Custom Panel Suffix
Contact Lutron for options
Rough-In Model Numbers
120/277 V
only
Example
S I N T 8 - 1 2 0 F T
Number of Circuits
in Panel
Feed
Voltage
Number of Circuits in Panel
Indicates number of switching circuits in the
panel:
8, 12, 16, 20, 24, 28, 32, 36, 40, 44, or 48
Feed Voltage
1, 2
Omit for dual voltage
120 for 120 V
277 for 277 V
Load Circuit Rating
16 A per circuit
2 Installation Guide for Switching Panels
(XPS)
TM
Feed-
Through
Type
Custom Panel
Suffix
Feed-
Through
Type
Branch Circuit Breaker Model Numbers
Example
X P S 2 4 - 1 2 0 4 M L - 2 0 - C G P _ _ _ _
Number of Circuits
in Panel
Feed
Voltage
Number of Circuits in Panel
Indicates number of switching circuits in the panel:
8, 12, 16, 20, 24 (all voltages)
28, 32, 36, 40, or 42 (120/277/347 V
Feed Voltage
120 for 120 V
230 for 230 V
(CE)
240 for 220-240 V
(non-CE)
277 for 277 V
347 for 347 V
Feed Type
4ML for 3 phase 4 wire main lugs
3ML for 1 phase 3 wire main lugs
4IS for 3 phase 4 wire isolation switch
Branch Circuit Rating
20 for 20 A branch circuit breakers (120/277/347 V
continuous load rating)
16 for 16 A branch circuit breakers (230/220-240 V
Custom Panel Suffix
Contact Lutron for options
Frequency - All Model Numbers and Voltages
50/60 Hz
Output Voltages
120 V
, 230 V
, 240 V
1
Multiple voltages (120 V
switched in the same panel. At least one feed of the
specified voltage is required for the low voltage control
transformer in the panel.
2
If voltage is not specified in the model number
(e.g., XPS24-FT) product is rated 120 V
277 V
. Refer to Wiring section.
Branch
Feed
Circuit
Type
Rating
Custom Panel
Suffix
only)
Input Ratings
120/208 V
or 277/480 V
or 230/400 V
or 220/380-240/415 V
120/240 V
, 277 V
, or 347 V
and 277 V
) may be
or
; 16 A
)
R