EN
It is important to select the correct
charging profile for your battery.
If you are still unsure what kind of
battery you have we recommend that
you contact the manufacturer of the
battery.
Charger's front display
Mode
ABS mode
EQUAL mode
End of EQUAL mode
FLOAT mode
OT default
(Over Temperature)
RP default
(Reverse Polarity)
OVO default
(Output Over Voltage)
17
LED
Status
Yellow
Batteries are charging. Time required to complete "Absorption"
depends on the initial SOC of the batteries, but it is limited to
8hrs
Yellow blinking
Batteries are coming to the end of the cycle charge. Time
required to complete "Equalization" depends on the initial SOC
of the batteries and varies between 30mn to 4hrs
Green blinking
Batteries are almost charged. Floating mode will begin in less
than 30mn
Green
Batteries are completely charged
Red slow
Charger is stopped for a period of 30sec min. The restart is
blinking
automatic once the defect has disappeared.
Check the external ambient temperature.
Green / red
Charger is stopped for a period of 30sec. The restart is
blinking
automatic once the defect has disappeared.
Check all connections and the polarity of the batteries.
Note that the internal battery fuse cannot be replaced.
Red fast
Charger is stopped for a period of 30sec. The restart is
blinking
automatic once the defect has disappeared.
Check the output voltage. In general, this default is
irreversible.