8. GENERAL CHARACTERISTICS

Power supply
I
1 battery 9 V 6F22, 6LR61 or NEDA 1604
I
Battery life:
6000 measurements lasting 10
seconds (with 9 V alkaline batteries)
3000 measurements lasting 10 seconds
(with 9V saline battery 6F22 as
supplied)
Buzzer :
I Series of 2 beeps for each change of
ranges.
I Continuous for continuity
Duration / Operating cycles:
I 690 VAC : unlimited operation
Climatic conditions:
I
Reference: 23°C ± 3°C
I
Use :
- temperature: -10°C to + 55°C
- relative humidity: < 96% RH
- altitude: up to 2000m
I
Storage:
- temperature: -10°C to 55°C (without battery)
Dimensions / Weight:
163 x 63.6 x 40mm / 210 g (battery included)
9. CONFORMITY WITH
INTERNATIONAL STANDARDS.
Voltage detector (as per 61243-3 - Ed.10/98
and NF EN 61010-1 2001 600 V CAT III)
Electrical safety
I Device as per NF EN 61010-1 : 2001
- Degree of pollution : 2
- Measurement category III for assigned voltage
600 V
I Device as per NF EN 61243-3:
- Class B
- Type: outdoor
I Cords as per NF EN 61010-1 : 2002
- Degree of pollution : 2
- Measurement category III for assigned voltage
1000V
Electric shock
(test as per IEC 1000-4-5)
I
6kV in differentail mode for function
voltmeter class B.