Example

9 - EMERGENCY MAN PRESENT OPERATION

This operational mode can be used to move the gate in Man Present mode in particular cases, such as installation/maintenance or in the
case of malfunctioning of photocell, edge, limit switches or encoder.
To start the "emergency" dead man operating mode activate the start command (START) for 3 seconds.
Strt
StAn
Note: if the
parameter is set as
, the Start command (from the terminal block or remote control) moves the gate in the
open and closed directions alternatively (unlike the normal Man Present mode).
Emergency man present mode ends after 10 seconds of the gate not moving.