8 - INSTALLATION MENÙ (
This menu allows you to perform the movements of the gate needed during installation.
The automatic learning procedure enables to save run limits based on data collected by the encoder.
The manual handling procedure allows to control the gate in hold to run mode in special cases such as during installation/maintenance or
a malfunction of the photocells or edges.
CAUTION: ATTENTION: before proceeding, make sure to position the mechanical stops and the limit sensors correctly.
1. Press and hold the OK key until the display shows
2. Release the OK key: the display shows
and i to select the menu
3. Use the keys
procedure of the run limits.
4. Press OK to start the selected procedure
8.1 - AUTOMATIC LEARNING OF THE RUN LIMITS
CAUTION: to perform the self-learning procedure it is necessary to disable the ADI interface by means of the menu i.Adi .
If some safeties are controlled by means of the ADI module, they will not be active during the self-teaching stage.
5. Press the OK key to activate the working time self-training cycle: the display shows the control panel and starts the time self-training
procedure.
5.1
The gate will be activated in closing direction until the stop end or the closing end of stroke is reached
5.2
The gate will be activated in opening direction until the stop end or the opening end of stroke is reached
5.3
The gate will be activated in closing direction until the stop end or the closing end of stroke is reached
6. If you DO NOT have enabled the obstacle sensor (menu
the control panel
7. If the obstacle sensor has been enabled, the display shows the recommended value for the obstacle sensor. If no operations are
performed for 20 seconds, the control unit exits the programming phase, without saving the value recommended.
8. The recommended value may be modified by pressing the
SEnS
display shows
9. Press and hold the i key until the display shows
programming mode, storing the value for the sensors.
PLEASE NOTE: If the control unit is left to time out from programming mode (1 minute), the obstacle sensor return to
the value that was set prior to performing self-training (according to the default values, the sensor is disabled).
On the other hand, the limit switch positions are always stored.
8.2 - MANUAL HANDLING
WARNING: when this procedure is activated the
safeties are not active.
MAn
5. The display shows
key to open the gate or the i button to close the gate
6. Press and hold the
7. Release the button to stop the gate
8. To exit this menu, press OK.
NOTE: If the motor is inactive for more than one minute the procedure terminates automatically.
SEt
)
-SEt
ESC
(only press the OK key if it is desired to exit this menu)
Mov
to activate manual handling or
SEnS
), the self-learning procedure is completed and the display shows
and i keys, and pressing the OK key confirms the displayed value and the
FinE
, then press the OK key, select the option
40
APPr
to start the automatic learning
Si
and then press the OK key to exit