Installer: please fi ll out appliance checklist in the

1.0 general information

When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specifi c recommendations
from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each
additional 1,000ft (305m). Expansion / contraction noises during heating up and cooling down cycles are normal
and are to be expected. Change in fl ame appearance from "HI" to "LO" is more evident in natural gas than in
propane.
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is certifi ed for mobile
home installation.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certifi ed kit is used.
note:
A barrier designed to reduce the risk of burns is provided with the appliance and must be installed. Never
operate the appliance without the barrier installed.
The protective wrap on plated parts is best removed when the assembly is at room temperature but this can
be improved if the assembly is warmed, using a hair dryer or similar heat source. The protective wrap must be
removed before operating the appliance.
This appliance is a decorative product. It is not a source of heat and not intended to burn solid fuel.
Batteries must be disposed of according to the local laws and regulations. Some batteries may be
recycled, and may be accepted for disposal at your local recycling center. Check with your
municipality for recycling instructions.
1.1
rates and effi ciencies
Altitude (FT)
Max. Input (BTU/HR)
Max. Output (BTU/HR)
Min. Inlet Gas Supply Pressure
Max. Inlet Gas Supply Pressure
Manifold Pressure (Under Flow Conditions)
* Max. inlet pressure not to exceed 13".
owner's manual.
GDIX4
NG
40,000
4.5" Water Column (11mb)
7" Water Column (17mb) *
3.5" Water Column (9mb)
general information
P
0-4,500
36,000
33,200
11" Water Column (27mb)
13" Water Column (32mb)
10" Water Column (25mb)