ENGLISH
The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
ELECTRICAL INSTALLATION + ADDRESSING
Important: The electrical installation should be carried out by qualified personal only,
according to the regulations for electrical and mechanical safety in your country.
Master / Slave mode:
Connect the projectors together as shown on the drawing. Please refer to the paragraph "SETUP MENU" to
setup the master. You can also switch the IR-remote on the master to ON and use the included IR-remote.
All slaves must be set to SLAVE-mode. You can put as many slaves as you like on condition that the overall
power consumption on the power line stays under 10A (2300W).
IMPORTANT: make sure that no DMX-controller is connected, this will result in unexpected behavior!
Electrical installation for two or more units in DMX-mode:
The DMX-protocol is a widely used high speed signal to control intelligent light equipment. You need to
"daisy chain" your DMX controller and all the connected units.
Pin layout XLR-3pin: Pin1 = GND ~ Pin2 = Negative signal (-) ~ Pin3 = Positive signal (+)
To prevent strange behavior of the light effects, due to interferences, you must use a
90Ω to 120Ω terminator at the end of the chain. Never use Y-splitter cables, this
simply won't work!
Make sure that all units are connected to the mains.
Each unit in the chain needs to have its proper starting address so it knows which
commands from the controller it has to decode. In the next section you will learn how to set the DMX
addresses.
HOW TO SETUP:
To select any of the functions, press the MODE button until the required function is shown on the display
or use the DOWN and UP buttons to browse the menu.
Select the function with the ENTER button.
Use DOWN and UP buttons to change the values.
Once the required value is selected, press the ENTER button to confirm.
BRITEQ
®
5/67
OPERATION MANUAL
COB SLIM100-RGB