ENGLISH
OPERATING INSTRUCTIONS
Note: when the projector is switched on the display shows "UPDATE WAIT ..." This message informs you
that IF you want to upgrade the firmware, you should do it while this message is shown on the display. For
normal use you can ignore this message completely.
A. Standalone 1unit:
Just connect the projector to the mains.
Select one of the standalone options, [AUTO RUN] [EFF MODE] or [STATIC]
Adjust the master dimmer [MASTER DIM] if necessary
Refer to chapter HOW TO SETUP to learn how to set the menu options.
It is also possible to use the IR remote controller in standalone mode. Just switch [IR REMOTE] in the
main menu of the unit to [ON]. You can now control the unit via the remote controller
B. Two or more units in master/slave setup:
Connect the units together. Refer to the chapter "electrical installation" to learn how to do this.
Select one of the standalone options, [AUTO RUN] [EFF MODE] or [STATIC] in the first projector of
the chain. This "Master" unit will send all the information to the slave units. This means all the main
program settings need to be done in this "Master" unit.
Adjust the master dimmer [MASTER DIM] if necessary
Set all the other projectors in SLAVE mode
The slave projectors will now follow the settings of the master projector so they all work
synchronously.
It is also possible to use the IR remote controller in master/slave mode. Just switch [IR REMOTE] in
the main menu of the master unit (the first one in the chain) to [ON]. You can now control the first
(master) unit via the remote controller, all the slave units will just follow.
C. Controlled by universal DMX-controller:
Connect all units together. Refer to the chapter "Electrical installation for two or more units in DMX-
mode" to learn how to do this (don't forget to address all units properly!)
Connect all units to the mains and turn on the DMX controller.
Since each unit has its own DMX-address, you can control them individually. Remember that each unit
can use a different number DMX-channels, depending on the DMX-mode you have selected in the
menu. See the different DMX charts below:
IMPORTANT:
The [IR REMOTE] setting in the menu should be set to [OFF]
3 channel DMX-Mode: RGB
Channel:
Value:
1
000-255
2
000-255
3
000-255
4LC channel DMX-Mode:
Note: This mode can be used with the JB Systems LEDCON-02 Mk2
Channel:
Value:
1
000-255
2
000-255
3
000-255
000-190
191-200
4
201-247
248-255
4+ channel DMX-Mode:
Channel:
Value:
1
000-255
2
000-255
3
000-255
4
000-255
BRITEQ
®
Function:
Red (0-100%)
Green (0-100%)
Blue (0-100%)
Function:
Red (0-100%)
Green (0-100%)
Blue (0-100%)
Master dimmer
Sound Control
Strobe
Master dimmer @ 100%
Function:
Red (0-100%)
Green (0-100%)
Blue (0-100%)
Master dimmer
11/67
OPERATION MANUAL
Remarks
Remarks
000=0% ~ 190=100% (full open)
7 colors
Increasing speed: 201=slow ~ 247=fast
Master dimmer is full open
Remarks
000=0% ~ 255=100% (full open)