2.2
Technical data
Voltage (± 9%)
Recommended circuit protection
Power consumption (maximum)
Temperature control
Probe maximum temperature
Time mode
Power range
Demagnetisation, automatic
Overall dimensions
Area between supports
Coil diameter
Weight (with yokes)
Workpiece maximum weight
Maximum heating temperature
Standard yoke dimensions
3
Installation of mains plug
Due to the many types of mains plugs, no mains plug is supplied with
the IH 210. A qualified electrician must install a suitable mains plug.
The correct supply voltage is shown in section 2.2.
The wires should be connected as follows:
22
200-230V/50-60Hz
400-460V/50-60Hz
500-575V/50-60Hz
50A circuit breaker (200-230V)
32A circuit breaker (400-460V)
25A circuit breaker (500-575V)
8.0kVA (200V/50-60Hz)
9.2kVA (230V/50Hz)
10.0kVA (400V/50Hz)
11.5kVA (460V/60Hz)
9.0kVA (500V/50Hz)
10.4kVA (575V/60Hz)
0-250°C (32-482°F) in steps of 1°
250°C (482°F)
0-60 minutes in steps of 0.1 minute
20 - 100% in steps of 20%
Residual magnetism < 2A/cm
600 x 350 x 420mm
250 x 250mm
135mm
75kg
Bearing 300kg, solid component 150kg
approx. 400°C (752°F)
70 x 70 x 420mm (for
40 x 40 x 420mm (for
Induction Heater IH 210
of 100mm)
Ø
of 60mm)
Ø
© simatec ag